Page 60 - Cardiac testing for coronary artery disease in potential kidney transplant recipients
P. 60
Jassal 2007 (Continued)
Notes Only data for the 18 patients referred for pre-renal transplant workup were considered.
Sufficient data in published report to create 2 x 2 table
Table of Methodological Quality
Item Authors’ judgement Description
Representative spectrum? Yes Patients who presented for cardiac evalua-
All tests tion before kidney transplantation
Acceptable reference standard? Yes Coronary angiography with a reference
All tests standard threshold of ≥ 50% stenosis
Acceptable delay between tests? Unclear Likely to be short delay between tests.
All tests
Partial verification avoided? Yes All participants who underwent the index
All tests test also had the reference standard test
Differential verification avoided? Yes Disease status (CAD) diagnosed by coro-
All tests nary angiography.
Incorporation avoided? Yes Disease status (CAD) diagnosed by coro-
All tests nary angiography.
Reference standard results blinded? Unclear Not reported.
All tests
Index test results blinded? Unclear Not reported.
All tests
Relevant clinical information? Yes Relevant clinical information was provided
All tests regarding the performance and analysis of
both the index and reference tests
Uninterpretable results reported? Yes No uninterpretable results were present.
All tests
Withdrawals explained? Yes No withdrawals were reported.
All tests
Cardiac testing for coronary artery disease in potential kidney transplant recipients (Review) 58
Copyright © 2011 The Cochrane Collaboration. Published by John Wiley & Sons, Ltd.