Page 79 - Cardiac testing for coronary artery disease in potential kidney transplant recipients
P. 79

West 2000  (Continued)



                 Item                           Authors’ judgement             Description

                 Representative spectrum?       Yes                            ESKD patients undergoing cardiac evalua-
                 All tests                                                     tion as part of transplant workup

                 Acceptable reference standard?  Yes                           Coronary artery stenosis measured by coro-
                 All tests                                                     naryangiography. CADdefinedasthe pres-
                                                                               ence of ≥ 1 coronary arteries with ≥ 70%
                                                                               diameter stenosis, or > 50% in left main
                                                                               coronary artery

                 Acceptable delay between tests?  Unclear                      Likely to be only delay between tests.
                 All tests

                 Partial verification avoided?   Yes                            All participants who underwent the index
                 All tests                                                     test received the reference standard test
                 Differential verification avoided?  Yes                        Disease status (CAD) diagnosed by coro-
                 All tests                                                     nary angiography.

                 Incorporation avoided?         Yes                            Disease status (CAD) diagnosed by coro-
                 All tests                                                     nary angiography.

                 Reference standard results blinded?  Unclear                  Not reported.
                 All tests
                 Index test results blinded?    Unclear                        Not reported.
                 All tests

                 Relevant clinical information?  Yes                           Relevant clinical information was provided
                 All tests                                                     regarding the performance and analysis of
                                                                               the index and reference tests

                 Uninterpretable results reported?  Yes                        There were no uninterpretable results.
                 All tests
                 Withdrawals explained?         Yes                            Nine patients were excluded because of
                 All tests                                                     prior coronary angiography (5), class III ±
                                                                               IV angina (3), and refusal to participate in
                                                                               the study (1)














                Cardiac testing for coronary artery disease in potential kidney transplant recipients (Review)  77
                Copyright © 2011 The Cochrane Collaboration. Published by John Wiley & Sons, Ltd.