rinsed in water, shaken to dry, and refilled at      shall be replenished using one half the number
          least each morning and afternoon or at least         of squeezes used initially (e.g., 5, 10 or 15).
          every four hours.
                                                               (10) The test subject shall indicate to the test
          (b) Bitrex Solution Aerosol Fit Test Procedure.      conductor if at any time during the fit test the
                                                               taste of Bitrex is detected. If the test subject
          (1) The test subject may not eat, drink (except      does not report tasting the Bitrex, the test is
          plain water), smoke, or chew gum for 15 min-         passed.
          utes before the test.
                                                               (11) If the taste of Bitrex is detected, the fit is
          (2) The fit test uses the same enclosure as that     deemed unsatisfactory and the test is failed. A
          described in 4. (a) above.                           different respirator shall be tried and the entire
                                                               test procedure is repeated (taste threshold
          (3) The test subject shall don the enclosure         screening and fit testing).
          while wearing the respirator selected according
          to section I. A. of this appendix. The respirator    5. Irritant Smoke (Stannic Chloride) Protocol
          shall be properly adjusted and equipped with
          any type particulate filter(s).                      This qualitative fit test uses a person’s response
                                                               to the irritating chemicals released in the
          (4) A second DeVilbiss Model 40 Inhalation           “smoke” produced by a stannic chloride venti-
          Medication Nebulizer or equivalent is used to        lation smoke tube to detect leakage into the
          spray the fit test solution into the enclosure.      respirator.
          This nebulizer shall be clearly marked to dis-
          tinguish it from the screening test solution         (a) General Requirements and Precautions
          nebulizer.
                                                               (1) The respirator to be tested shall be
          (5) The fit test solution is prepared by adding      equipped with high efficiency particulate air
          337.5 mg of Bitrex to 200 ml of a 5% salt            (HEPA) or P100 series filter(s).
          (NaCl) solution in warm water.
                                                               (2) Only stannic chloride smoke tubes shall be
          (6) As before, the test subject shall breathe        used for this protocol.
          through his or her slightly open mouth with
          tongue extended, and be instructed to report if      (3) No form of test enclosure or hood for the
          he/she tastes the bitter taste of Bitrex.            test subject shall be used.

          (7) The nebulizer is inserted into the hole in the   (4) The smoke can be irritating to the eyes,
          front of the enclosure and an initial concentra-     lungs, and nasal passages. The test conductor
          tion of the fit test solution is sprayed into the    shall take precautions to minimize the test
          enclosure using the same number of squeezes          subject’s exposure to irritant smoke. Sensitivity
          (either 10, 20 or 30 squeezes) based on the          varies, and certain individuals may respond to a
          number of squeezes required to elicit a taste re-    greater degree to irritant smoke. Care shall be
          sponse as noted during the screening test.           taken when performing the sensitivity screening
                                                               checks that determine whether the test subject can
          (8) After generating the aerosol, the test subject   detect irritant smoke to use only the minimum
          shall be instructed to perform the exercises in      amount of smoke necessary to elicit a response
          section I. A. 14. of this appendix.                  from the test subject.


          (9) Every 30 seconds the aerosol concentration       (5) The fit test shall be performed in an area with