              Bibliographic details   Study type &   Patient characteristics   Test, Reference Standard,   Results                Reviewers Comments
                                Evidence level                            Threshold for a positive test
                                             median BW 3295 g – range 1972 to 4720   TcB measurement   Bland Altman analysis for difference
              44                             median GA 39 weeks – range 33 to 42                   between lab TSB and TcB
                                             median postnatal age: 72 hours – range   Diagnostic accuracy of TcB
                                             24 to 264                    (various thresholds) estimated by   MD = -10.6 micromol/litre (95% CI -80.0 to
                                             Gender: Males = 50%          plotting ROC curve.      +60.0)
                                                                                                   SD = Not reported
                                             Prevalence of TSB >
                                             250 micromol/litre = 55/300 (18.3%)                   Diagnostic accuracy of TcB (threshold value
                                                                                                   > 195 micromol/litre) for detecting TSB >
                                             Exclusion: babies who had previously                  250 micromol/litre
                                             received phototherapy
                                                                                                   Sensitivity: 50/55 (90.9%)
                                                                                                   Specificity: 162/245 (66.1%)
                                                                                                   PPV: 50/133 (37.6%)
                                                                                                   NPV: 162/167 (97%)

              De Luca D;        Study Type:   Preterm babies with GA between 30–  TcB using BiliChek from the   Correlation of TcB levels with lab TSB   Unselected population
                                Diagnostic study   36 weeks admitted in the neonatal sub-  forehead – mean of 5   levels (Pearson correlation coefficient,   Test & Reference test described
              Year: 2007                     intensive unit of tertiary hospital.   measurements taken for data   n = 210)        adequately
                                Evidence Level:                           analysis.                                               Test and reference test carried
              Country:          Ib           n = 340                                               r = 0.79, P < 0.001            out within one hour
              Italy                          mean BW 2145 ± 518 g         Reference standard: Laboratory                          Blinding – yes but only
                                                                          TSB levels within 10 minutes of   Bland Altman analysis for difference   investigator
              79                             mean GA 33.5 ± 1.9 weeks     TcB measurement          between mean lab TSB and mean TcB   Data not extractable for
                                             mean postnatal age: Not reported                      % with difference              calculating values of TP, FP,
                                             Gender: Males = 48.2%        Diagnostic accuracy of TcB   > 8.55 micromol/litre = 61.5% (209/340)   TN & FN for detecting
                                                                          estimated by plotting ROC curve   MD = -18.8 micromol/litre   hyperbilirubinaemia
                                             Exclusion:                   and results given for best   SD = 34.2 micromol/litre
                                             babies receiving phototherapy or   thresholds
                                             exchange transfusion,                                 Diagnostic accuracy of TcB (threshold value
                                             asphyxia (Apgar score < 7 at 5 min),                  > 111 micromol/litre) for detecting TSB >
                                             Rh or major ABO incompatibility,                      171 micromol/litre
                                             conjugated bilirubin
                                             > 17.1 micromol/litre,                                Sensitivity: 100%
                                             congenital malformation,                              Specificity: 40%
                                             liver disease.
                                                                                                   Diagnostic accuracy of TcB (threshold value
                                                                                                   > 171 micromol/litre) for detecting TSB >
                                                                                                   205 micromol/litre

                                                                                                   Sensitivity: 100%
                                                                                                   Specificity: 72%

              Karon B;          Study Type:   Babies in a well-infant nursery were   Test:         Correlation of TcB levels with TSB levels   Unselected population
                                Diagnostic study   eligible if a serum bilirubin was ordered   TcB reading from the forehead   (Pearson correlation coefficient, n = 177)   Test & Reference test described
              Year: 2008                     to assess risk of hyperbilirubinaemia.   using BiliChek – mean of 5                  adequately
                                Evidence Level:                           measurements taken for data   Forehead                  Test and reference test carried
              Country: USA      III          n = 177                      analysis                 Diazo: r² = 0.65               out within one hour


            240