of, the canister.  The degree of protection shall be marked as the percent of penetration of the canister
                 by a 0.3-micron-diameter dioctyl phthalate (DOP) smoke at a flow rate of 85 liters per minute.


                 (5) Each canister shall have a label warning that gas masks should be used only in atmospheres
                 containing sufficient oxygen to support life (at least 16 percent by volume), since gas mask canisters are
                 only designed to neutralize or remove contaminants from the air.

                 (6) Each gas mask canister shall be painted a distinctive color or combination of colors indicated in
                 Table I-1.  All colors used shall be such that they are clearly identifiable by the user and clearly
                 distinguishable from one another.  The color coating used shall offer a high degree of resistance to
                 chipping, scaling, peeling, blistering, fading, and the effects of the ordinary atmospheres to which
                 they may be exposed under normal conditions of storage and use.  Appropriately colored pressure
                 sensitive tape may be used or the stripes.