Page 85 - Cardiac testing for coronary artery disease in potential kidney transplant recipients
P. 85
D A T A
Presented below are all the data for all of the tests entered into the review.
Tests. Data tables by test
No. of No. of
Test studies participants
1 DSE 13 745
2 MPS 9 582
3 EST 2 129
4 EBCT 1 97
5 DSF 1 86
6 EV 1 35
7 CIMT 1 105
8 Echo (RWMA) 2 265
9 Echo (LV) 1 52
10 Echo (MAC) 1 125
11 ECG 3 263
Test 1. DSE.
Review: Cardiac testing for coronary artery disease in potential kidney transplant recipients
Test: 1 DSE
Study TP FP FN TN Sensitivity Specificity Sensitivity Specificity
Bates 1996 9 1 1 6 0.90 [ 0.55, 1.00 ] 0.86 [ 0.42, 1.00 ]
Brennan 1997 4 1 2 5 0.67 [ 0.22, 0.96 ] 0.83 [ 0.36, 1.00 ]
Cai 2010 15 2 8 13 0.65 [ 0.43, 0.84 ] 0.87 [ 0.60, 0.98 ]
De Lima 2003 15 7 19 48 0.44 [ 0.27, 0.62 ] 0.87 [ 0.76, 0.95 ]
Ferreira 2007 24 14 10 78 0.71 [ 0.53, 0.85 ] 0.85 [ 0.76, 0.91 ]
Gang 2007 9 1 10 20 0.47 [ 0.24, 0.71 ] 0.95 [ 0.76, 1.00 ]
Garcia-Canton 1998 11 2 1 13 0.92 [ 0.62, 1.00 ] 0.87 [ 0.60, 0.98 ]
Herzog 1999 12 8 4 26 0.75 [ 0.48, 0.93 ] 0.76 [ 0.59, 0.89 ]
Jassal 2007 0 0 0 18 Not estimable 1.00 [ 0.81, 1.00 ]
Reis 1995 22 1 1 6 0.96 [ 0.78, 1.00 ] 0.86 [ 0.42, 1.00 ]
Sharma 2005 32 5 4 84 0.89 [ 0.74, 0.97 ] 0.94 [ 0.87, 0.98 ]
0 0.2 0.4 0.6 0.8 1 0 0.2 0.4 0.6 0.8 1
(Continued . . . )
Cardiac testing for coronary artery disease in potential kidney transplant recipients (Review) 83
Copyright © 2011 The Cochrane Collaboration. Published by John Wiley & Sons, Ltd.