Page 38 - L:\GROUP\SDT\zip_disk\Book2.PDF
P. 38

Inspection During Cleaning
                 J.   Make sure that the gaskets fit prop-     Inspection During Cleaning
          erly in the filter holders.
                                                               The respirator must also be inspected during
                 K.  If the filters seal directly against the  cleaning:
          facepiece, be sure that the sealing surface is not
          torn, chipped, cut, or otherwise damaged.            1.  Use the same inspection procedures followed
                                                               before and after each use, but remove all parts
                 L.   Inspect the filters to be sure that the  of the respirator from the mask and check for
          threads are not scratched, chipped, dented, or       dirt, damage, and nonflexibility.
          otherwise damaged.
                                                               2.  Replace defective parts.
                 Inspect PAPRs as follows:
                                                               3.  Thoroughly wash, disinfect, and reassemble
                 A.  Stretch out the corrugated breathing      the parts and mask.
          tube to inspect it for cuts, abrasions, and pin-
          holes.
                                                                                              A
                                                                               Repairing,epairing,
                                                                                                    S
                                                                 Cleaning,leaning,
                                                                 C             R              Andnd  Storingtoring
                                                                 Respirators Used For Protection
                 B.  Inspect the blower assembly and             Respirators Used For Protection
          batteries as described by the manufacturer.            Against TB
                                                                 Against TB
                 C.  The inspection procedures for half-
          masks and full facepieces used with PAPRs are        I Introductionntroduction
          the same as those described above.
                                                               The OSHA respirator regulation (see Appendix
                 D.   If the PAPR is equipped with a hood      A) requires that respirators be properly cleaned,
          or helmet, inspect according to the manu-            repaired, and stored.  A proper maintenance pro-
          facturer’s instructions.                             gram ensures that the worker’s respirator remains
                                                               as effective as when it was new.

                 Inspect supplied-air respirators as
                                                               Cleaning
                 follows:                                      Cleaning
                 A.   The inspection procedures for            Generally, disposable respirators do not need to
          half-masks and full facepieces used with             be cleaned or maintained.  If they are soiled or
          supplied-air devices are the same as those           otherwise damaged they are discarded.  How-
          described for air-purifying respirators (ex-         ever, some manufacturers make disposable res-
          cluding filter cartridges).  If the respirator       pirators that look like replaceable respirators
          is equipped with a  corrugated hose, stretch         (filters cannot be removed or replacement parts
          it out and inspect for cuts, abrasions, and          are not available) and the facepiece may require
          pinholes.                                            some cleaning.


                 B.  Check the condition of the air            Replaceable filter respirators must be carefully
          supply hose, including attachments and               maintained. The manufacturer’s recommenda-
          end fittings.                                        tions should be followed to ensure proper func-
                                                               tioning of the respirator. The following discus-
                 C.   Check the regulator as described by      sion of maintenance procedures should help
          the manufacturer.                                    users understand the overall process: