Page 118 - L:\GROUP\SDT\zip_disk\Book2.PDF
P. 118

feedback in the form of a real-time pressure         (7) The QNFT protocol shall be followed ac-
          trace of the in-mask pressure is provided and        cording to section I. C. 1. of this appendix with
          used to determine test validity and quality. A       an exception for the CNP test exercises.
          minimum fit factor pass level of 100 is neces-
          sary for a half-mask respirator and a mini-          (b) CNP Test Exercises.
          mum fit factor of at least 500 is required for a
          full facepiece respirator. The entire screening      (1) Normal breathing. In a normal standing
          and testing procedure shall be explained to the      position, without talking, the subject shall
          test subject prior to the conduct of the screening   breathe normally for 1 minute. After the nor-
          test.                                                mal breathing exercise, the subject needs to
                                                               hold head straight ahead and hold his or her
          (a) CNP Fit Test Requirements.                       breath for 10 seconds during the test measure-
                                                               ment.
          (1) The instrument shall have a non-adjustable
          test pressure of 15.0 mm water pressure.             (2) Deep breathing. In a normal standing posi-
                                                               tion, the subject shall breathe slowly and
          (2) The CNP system defaults selected for test        deeply for 1 minute, being careful not to hy-
          pressure shall be set at — 15 mm of water (-         perventilate. After the deep breathing exercise,
          0.58 inches of water) and the modeled inspira-       the subject shall hold his or her head straight
          tory flow rate shall be 53.8 liters per minute       ahead and hold his or her breath for 10 sec-
          for performing fit tests.                            onds during test measurement.


          (Note: CNP systems have built-in capability to       (3) Turning head side to side. Standing in
          conduct fit testing that is specific to unique       place, the subject shall slowly turn his or
          work rate, mask, and gender situations that          her head from side to side between the ex-
          might apply in a specific workplace. Use of          treme positions on each side for 1 minute.
          system default values, which were selected to        The head shall be held at each extreme mo-
          represent respirator wear with medium car-           mentarily so the subject can inhale at each
          tridge resistance at a low-moderate work rate,       side. After the turning head side to side ex-
          will allow inter- test comparison of the respira-    ercise, the subject needs to hold head full
          tor fit.)                                            left and hold his or her breath for 10 sec-
                                                               onds during test measurement. Next, the
          (3) The individual who conducts the CNP fit          subject needs to hold head full right and
          testing shall be thoroughly trained to perform       hold his or her breath for 10 seconds during
          the test.                                            test measurement.

          (4) The respirator filter or cartridge needs to be   (4) Moving head up and down. Standing in
          replaced with the CNP test manifold. The inha-       place, the subject shall slowly move his or
          lation valve downstream from the manifold ei-        her head up and down for 1 minute. The
          ther needs to be temporarily removed or              subject shall be instructed to inhale in the
          propped open.                                        up position (i.e., when looking toward the
                                                               ceiling). After the moving head up and
          (5) The test subject shall be trained to hold his    down exercise, the subject shall hold his or
          or her breath for at least 20 seconds.               her head full up and hold his or her breath
                                                               for 10 seconds during test measurement.
          (6) The test subject shall don the test respirator   Next, the subject shall hold his or her head
          without any assistance from the individual           full down and hold his or her breath for 10
          who conducts the CNP fit test.                       seconds during test measurement.


                                                           110
   113   114   115   116   117   118   119   120