Page 650 - 16Neonatal Jaundice_compressed
P. 650

Appendix J: Excluded studies


 Reference                        Reason for exclusion
 Surjono A, Triasih R, and Haksari EL. The first 24 hours bilirubin level as a predictor of hyperbilirubinemia in healthy term   Incomplete data
 newborns. Perinatology 2003; 5:(4)159–66.
 Taha SA, Karrar ZA, and Dost SM. Transcutaneous bilirubin measurement in evaluating neonatal jaundice among Saudi   Duplicate publication
 newborns. Annals of Tropical Paediatrics 1984; 4:(4)229–31.
 Tan KL and Dong F. Transcutaneous bilirubinometry during and after phototherapy. Acta Paediatrica, International Journal of   Use of transcutaneous bilirubinometer during and
 Paediatrics 2003; 92:(3)327–31.   after phototherapy
 Tan KL, Chia HP, and Koh BC. Transcutaneous bilirubinometry in Chinese, Malay and Indian infants. Acta Paediatrica,   Incomplete data – data not available for 262
 International Journal of Paediatrics 1996; 85:(8)986–90.   babies
 Tan KL. Neonatal jaundice in 'healthy' very low birthweight infants. Australian Paediatric Journal 1987; 23:(3)185–8.   No comparison goup
 Tan KL. Transcutaneous bilirubinometry in Chinese and Malay neonates. Annals of the Academy of Medicine Singapore 1985;   Some babies had been exposed to phototherapy
 14:(4)591–4.
 Venkataseshan S, Murki S, and Kumar P. Non-invasive bilirubinometry in neonates. Perinatology 2004; 6:(6)315–9.   Commentary
 Wainer S, Bolton KD, Cooper PA et al. Transcutaneous bilirubinometry in black infants: Improved reliability after correction for   Importance of background signal in
 the background signal. Pediatric Reviews and Communications 1989; 4:(1–2)93–2.   transcutaneous bilirubin measurements
 Wainer S, Rabi J, Lyon M et al. Coombs' testing and neonatal hyperbilirubinemia... Sgro M, Campbell D, Shah V. Incidence and   Correspondence
 causes of severe hyperbilirubinemia in Canada. CMAJ 2006;175(6):587–90. CMAJ: Canadian Medical Association Journal 2007;
 176:(7)972–3, 976.
 Webster J, Blyth R, and Nugent F. An appraisal of the use of the Kramer's scale in predicting hyperbilirubinaemia in healthy full   Data not extractable
 term infants. Birth Issues 2005; 14:(3)83–9.
 Willems WA, Von D, De W et al. Transcutaneous bilirubinometry with the Bilicheck in very premature newborns. Journal of   Data not relevant
 Maternal-Fetal and Neonatal Medicine 2004; 16:(4)-Fetal.
 Wong CM, Van Dijk P, and Laing IA. A comparison of transcutaneous bilirubinometers: SpectRx BiliCheck versus Minolta   Poor quality study – EL 3
 AirShields. Archives of Disease in Childhood: Fetal and Neonatal Edition 2002; 87:(2)F137-F140.
 Wong V, Chen WX, and Wong KY. Short- and long-term outcome of severe neonatal nonhemolytic hyperbilirubinemia. Journal of  Outcomes of severe  hyperbilirubinaemia
 Child Neurology 2006; 21:(4)309–15.
 Yamauchi Y and Yamanouchi I. Clinical application of transcutaneous bilirubin measurement. Early prediction of   Poor quality study – EL 3
 hyperbilirubinemia. Acta Paediatrica Scandinavica 1990; 79:(4)385–90.
 Yamauchi Y and Yamanouchi I. Transcutaneous bilirubinometry in normal Japanese infants. Acta Paediatrica Japonica (Overseas  Time between compared tests greater than 1 hour
 Edition) 1989; 31:(Overseas Edition)65–72.
 Yamauchi Y and Yamanouchi I. Transcutaneous bilirubinometry: serum bilirubin measurement using transcutaneous   Test of different curvettes for Minolta JM
 bilirubinometer (TcB). A preliminary study. Biology of the Neonate 1989; 56:(5)257–62.
 Yap SH, Mohammad I, and Ryan CA. Avoiding painful blood sampling in neonates by transcutaneous bilirubinometry. Irish   Unclear of time between testing
 Journal of Medical Science 2002; 171:(4)188–90.
 Yasuda S, Itoh S, Isobe K et al. New transcutaneous jaundice device with two optical paths. Journal of Perinatal Medicine 2003;   No possible to extract data
 31:(1)81–8.




                                                                       469