Standard Operating Procedure # ____
                Maintenance Of Brand ___________ Replaceable Filter Half-Mask Respirator




             Hospital name: ________________________________


             Address: ______________________________________
                           ______________________________________


             Program administrator (or other designated author) _________________________

             Date SOP written _______________


             Date signed by program administrator _______________


             Date to be reviewed ________________







             Disassembly:

             1.      Have central supply personnel collect used respirators at the designated collection points located
                     in the hallway of each TB isolation room.


             2.      Take used respirators to the respirator maintenance area in central supply.

             3.      Remove all parts from the respirator as recommended by the manufacturer:


                     A.  Filters and gaskets
                     B.  Exhalation valve cover
                     C.  Inhalation and exhalation valves
                     D.  Speaking diaphragm
                     E.  Elastic straps (headbands)
                     F.  Facepiece


             4.      Inspect the respirator for damaged and defective parts; discard them if found.  Replacement parts
                     must be identical to the original parts, or NIOSH-accepted alternatives obtained from the
                     respirator manufacturer.


                     A.     Check the filters for damage (dents or cracks), filter soiling, and damaged     threads
                            (scratched, chipped, or dented).  Inspect the gaskets for pliability and wear.


                     B.     Check the exhalation valve cover for defects.